| OPERATIONAfter the retort base is loaded the top hat retort is
    lowered onto the base and clamped. That retort is then purged. The shuttle device with the
    furnace is moved over the loaded retort and lowered down. The furnace then heats up the
    retort. When the load is done the furnace is lifted up and moved over to resting base.
    After cooling and purging the retort is lifted up off the base and the base is unloaded. FEATURESFURNACE CONSTRUCTIONThe furnace is made of polygonal heater sections with a stainless steel wrap
    around casing. These are supported in heavy metal frame that completely supports and
    protects these heaters.
 BELL/SHUTTLE LIFT DESIGN The furnace is lifted up by an integral electric hoist which is mounted on a
    shuttle device. This shuttle device, made of structural steel, shuttles between two
    separate bases. The movement of the shuttle device is by hand operation. Clamps hold the
    furnace shuttle in place.
 FURNACE/RETORT BASEOne base assembly has an insulated retort plug bottom. The retort bell jar
    cover goes over this plug bottom and gets bolted down to the bottom with swing away quick
    release clamps. The bottom has all the water cooling channels, thermowells and gas
    atmosphere connections so that these do not need to move.
 PARKING BASEA separate base is provided to park the heated furnace.
 INSULATION SYSTEMThe furnace is insulated with 2-1/2 of low K factor refractory
    firebrick with 2 of backup mineral wool. No asbestos or asbestos products are used.
 IRON-ALUMINUM-CHROME ELEMENTSThese are excellent for high temperature applications. An oxide coating
    protects the element. The elements are supported in proprietary ceramic element holders.
    These provide perfect support for the coiled element as well as excellent radiating
    characteristics. The smooth surface prevents premature failure of the element as it
    expands and contracts. Elements are evenly spaced around the perimeter of the furnace and
    are zoned.
 HEARTHThe top of the insulated plug is designed to take up to the rated load. If a
    fan is used there is a grid above fan.
 BELL ATMOSPHERE TOP HAT RETORTThere is an alloy round atmosphere tight retort designed for combustible or
    inert low dew point atmospheres. The type of alloy used is dependent on the temperature
    and application. Inlet and outlet are mounted through the bottom base assembly. The base
    features an insulation plug which is completely covered with alloy so that no water vapor
    can get trapped in the insulation and outgas to the chamber. There is a silicone rubber
    O ring seal around the perimeter of the retort. This is cooled by water which
    runs in an enclosed channel around the perimeter of the base. The retort is secured with
    quick release bolt down latches. This forms an extremely tight seal and allows very low
    dew point operation.
 ATMOSPHERE SAMPLE PORTA sample port is provided. There is a valve to close this off when not in
    use. This is used to sample the atmosphere for oxygen, hydrogen, dew point, etc.
 ATMOSPHERE CONTROLA variety of atmosphere control systems can be provided. See Bulletin H2
    which describes the hydrogen flow control system or Bulletin MPH for information on a
    mixing panel for forming gas. In addition, simple regulators/flowmeters can be provided
    for inert gas use.
 DIGITAL PID CONTROL SYSTEMThe standard control is a Honeywell UDC 2000 digital PID 3 mode tuning
    control. All fuses, transformers, contactors, and controls are housed in a floor mounted
    NEMA 1 panel. If hydrogen is used then a purged NEMA 12 control panel is standard. Quiet,
    long life mercury power contactors are standard, but the SCR power control option is
    recommended (preferably with zoned control for high uniformity.) The thermocouple is Type
    K and is located inside the retort for accurate control of process temperature.
    Thermocouple break protection is included. Control voltage is transformed to 120 volts. A
    NEMA 13 lighted On/Off switch is included. The control circuit and each power branch
    circuit are fully fused. Honeywell UDC 2000 digital high limit back up control with manual
    reset, back up contactors and separate thermocouple included. NEMA 1 panels must be
    connected to a fused power supply. NEMA 12 panels have a fused disconnect switch.
 TESTING AND INSTRUCTIONSFurnace is completely tested at the factory. A complete instruction manual
    includes easy start up instructions, theory of operation, maintenance instructions, parts
    list, and a detailed trouble shooting guide. A ladder logic diagram and panel layout are
    prepared on CAD for easy readability.
 WARRANTYThe furnace is warranted for one year except for elements, retort and
    thermocouples (warranted for 6 months.)
 OPTIONS
      CONTROL, RECORDER AND ELECTRICAL OPTIONSSCR POWER CONTROLWATER COOLED FAN: Industrial Gas Engineering AMX water cooled
        fan. This is located in the base of the unit. Can provide up to +/-10F uniformity.ON SITE START UP AND TRAINING   |